Jotun Penguard

Availability: In Stock

£48.83

This is a two component, polyamide cured, high molecular weight epoxy coating. Designed as a primer for new
construction. Can be used as primer as a part of a complete system in atmospheric and immersed environments.
Suitable for properly prepared carbon steel, stainless steel, aluminium, concrete, galvanised steel, shop primed
steel and thermally sprayed zinc substrates.
Approvals and certificates
When used as part of an approved scheme, this material has the following certification:
– Low Flame Spread in accordance with EU Directive for Marine Equipment. Approved in accordance with parts 5
and 2 of Annex 1 of IMO 2010 FTP Code, or Parts 5 and 2 of Annex 1 of IMO FTPC when in compliance with
IMO 2010 FTP Code Ch. 8

Order Jotun Penguard today!

Refer to data sheets for further information or any other questions on Penguard or any of the Jotun range contact the team on 01752 690997 or at [email protected]

This is a two component, polyamide cured, high molecular weight epoxy coating. Designed as a primer for new
construction. Can be used as primer as a part of a complete system in atmospheric and immersed environments.
Suitable for properly prepared carbon steel, stainless steel, aluminium, concrete, galvanised steel, shop primed
steel and thermally sprayed zinc substrates.
Approvals and certificates
When used as part of an approved scheme, this material has the following certification:
– Low Flame Spread in accordance with EU Directive for Marine Equipment. Approved in accordance with parts 5
and 2 of Annex 1 of IMO 2010 FTP Code, or Parts 5 and 2 of Annex 1 of IMO FTPC when in compliance with
IMO 2010 FTP Code Ch. 8

Product data

Property                            |Test/Standard      |     Description


Solids by volume            | ISO 3233     |      51 ± 2%

Gloss level (GU 60 ° )   | ISO 2813     |     matt (0-35)

Flash Point                     | ISO 3679 Method 1     |     25°c

Density                            | calculated     |     1.3kg/l

VOC-US/Hong Kong    | US EPA method 24 (tested)     |     440 g/l

(CARB(SCM)2007, SCAQMD rule 1113, Hong Kong )

VOC-EU                          | IED (2010/75/EU) (theoretical)     |     456 g/l

VOC-China                     |GB/T 23985 – 2009 (tested)     |     415 g/l

VOC-Korea                     | Korea Clean Air Conservation Act (tested)     |     424 g/l

(Max. thinning ratio included)

To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any
contamination

SubstrateSurface Preparation – MinimumSurface Preparation – Recommended
Carbon steelSt 2 (ISO 8501-1)Sa 2½ (ISO 8501-1)
Stainless steel                                    The surface shall be hand or machine abraded, with non-metallic abrasives or bonded fibre machine or hand abrasive pads to impart a scratch pattern to the surface.Abrasive blast cleaning to achieve a surface profile using non-metallic abrasive media which is suitable to achieve a sharp and angular surface profile.
Aluminium                                                         The surface shall be hand or machine abraded with non-metallic abrasives or bonded fibre machine or hand abrasive pads to impart a scratch pattern to the surface.Abrasive blast cleaning to achieve a surface profile using non-metallic abrasive media which is suitable to achieve a sharp and angular surface profile.
Galvanised steel                           The surface shall be clean, dry, and appear with a rough and dull profile. Sweep blast-cleaning using non-metallic abrasive leaving a clean, rough, and even pattern.
Shop primed steel   Dry, clean, and intact shop primer.Sweep blasted or alternatively blasted to Sa 2 (ISO 8501-1) of at least 70% of the surface.
Coated surfaces                                     Clean, dry, and undamaged compatible coating.Clean, dry, and undamaged compatible coating.
Concrete                                              Moisture content maximum 5%. Mechanically prepare the existing concrete surface by scabbling, needle gun, mechanical disc grinding.Minimum 4 weeks curing.  Moisture content maximum 5%. Prepare the surface by means of enclosed blast shot or diamond grinding and other appropriate means to abrade the surrounding concrete and to remove laitance.

Order Jotun Penguard today!

Refer to data sheets for further information or any other questions on Penguard or any of the Jotun range contact the team on 01752 690997 or at [email protected]

 

size

5L, 20L ( contact the team direct)

colour

Grey, Red or white available contact sales team for more information

coating type

Primer

Internal or external

Designed for external but can be used for internal

what is its use?

Manufactured for the Jotun Steel-Master range of intumescent paints